Air Intake
Standard repair procedures
Last updated
Standard repair procedures
Last updated
Chemical film material
Epoxy polyamide primer
Sealant
Examine the Inlet Barrier Filter (IBF) structural assembly for damage on two sides of the assembly.
If the filter is damaged, continue as follows
Remove the filter assembly from the IBF structural assembly.
If the IBF web structure is damaged, drill through the sheet metal structure until the damage diameter.
If the corner brackets of the IBF assembly are damaged, do as follows
If the damage is less than 0.004 inch (0.102 mm), blend the damage smooth. Keep 10 to 1 minimum width to depth ratio.
If the damage is more than 0.004 inch (0.102 mm), replace the side angles as follows
Remove the rivets and side angles.
Wet install the replacement side angles and rivets in .
Apply and to the bare metal surfaces. Seal all the edges that connect with .
Install the filters of the Inlet Barrier Filter IBF assembly.