Non-Destructive Inspections
This section gives the procedure and data necessary to detect faults such as cracks.
Nomenclature | Part Number |
---|---|
Latches | 206-010-121-005 |
Trunnion | 206-011-120-105 |
Pin | 206-011-125-003 |
Blade bolt | 206-011-135-105 |
Yoke | 206-011-149-105 |
Strap bolt | 206-011-206-101 |
Strap fitting | SLS-010-150-103 |
Main Procedure
Discard all the parts that fail the Non-Destructive Inspection (NDI) criteria.
Magnetic Particle Inspection (MPI)
Do a Magnetic Particle Inspection (MPI) for the applicable parts, in accordance with the 505-CMM and in the BHT-ALL-SPM, Chapter 6, Standard Practices Manual.
Fluorescent Penetrant Inspection (FPI)
Do a Fluorescent Penetrant Inspection (FPI) for the applicable parts, in accordance with the 505-CMM and in the BHT-ALL-SPM, Chapter 6, Standard Practices Manual.
Requirements After Job Completion
Use a gauss meter to make sure magnetization of the parts is less than 3 gauss anywhere on the part. Otherwise, demagnetize the part per the instructions contained in the BHT-ALL-SPM, Chapter 6, Standard Practices Manual.