Non-Destructive Inspections

This section gives the procedure and data necessary to detect faults such as cracks.

NomenclaturePart Number

Latches

206-010-121-005

Trunnion

206-011-120-105

Pin

206-011-125-003

Blade bolt

206-011-135-105

Yoke

206-011-149-105

Strap bolt

206-011-206-101

Strap fitting

SLS-010-150-103

Main Procedure

Discard all the parts that fail the Non-Destructive Inspection (NDI) criteria.

Magnetic Particle Inspection (MPI)

Do a Magnetic Particle Inspection (MPI) for the applicable parts, in accordance with the 505-CMM and in the BHT-ALL-SPM, Chapter 6, Standard Practices Manual.

Fluorescent Penetrant Inspection (FPI)

Do a Fluorescent Penetrant Inspection (FPI) for the applicable parts, in accordance with the 505-CMM and in the BHT-ALL-SPM, Chapter 6, Standard Practices Manual.

Requirements After Job Completion

Use a gauss meter to make sure magnetization of the parts is less than 3 gauss anywhere on the part. Otherwise, demagnetize the part per the instructions contained in the BHT-ALL-SPM, Chapter 6, Standard Practices Manual.