Lubricating the pillow block assemblies

Preliminary requirements

Support equipment

NomenclatureIdentification No.Qty

Grease gun

Commercial

1

Consumables, materials and expendables

NomenclatureIdentification No.Qty

Grease

C-172

AR

Safety conditions

MAKE SURE TO OBEY ALL THE GREASE LUBRICATION PRACTICES BEFORE YOU LUBRICATE THE COMPONENT WITH GREASE. IF NOT, DAMAGE TO THE COMPONENT CAN OCCUR.

Procedure

DO NOT APPLY THE GREASE QUICKLY. APPLY THE GREASE QUICKLY CAN CAUSE PRESSURIZATION OF THE GREASE CAVITIES AND THAT CAN RESULT IN: PUSHING THE GREASE THROUGH THE SEAL, POPPING OR PUSHING OUT THE SEALS, DAMAGE TO THE SEALS, OR OTHER UNWANTED EFFECTS.

This procedure is the same for all pillow block assemblies.

  1. Lubricate the pillow block assembly as follows:

    1. Slowly put grease (C-172) into the lubrication fitting, with a grease gun, until all of the old grease is fully replaced. Collect and discard the old grease when it comes out of the bearing.

    2. Clean the area.

Last updated