Flushing the hydraulic system

Preliminary requirements

Support equipment

NameIdentification/ReferencesQuantityRemark

Extraction syringe

Commercial

1

Syringe 7075 from CTA Manufacturing Corp or equivalent.

Container

Commercial

1

Spares

NameIdentification/ReferencesQuantity

Procedure

It is normal for the reservoir to fill and overflow at the inlet when using the HPU. The time to fill is dependent on the length

  1. Set hydraulic pressure on cart to 400 psi and flow rate at 2.0 GPM +/- 0.5 GPM and cycle the actuators to full stroke for 5 minutes.

  2. Repeat step 3.

  3. Disconnect the pressure line (to HRFM) at the hydraulic pump, pressure filter assembly, and check valve and allow draining.

  4. Reconnect the suction (M206-20H102-041) and pressure lines (M206-20H101-041) to the pump.

  5. Turn the rotor by hand to remove air.

  6. Do a 15-minute ground run of the helicopter.

  7. Take fluid samples from the HRFM reservoir and analyze for particle contamination. Contamination level shall be less than the levels defined in Table 1.

Table 1. Cleanliness Requirements for Synthetic Hydrocarbon Based Hydraulic Fluid Systems

Particle Size (microns)Number of Particles (in 100ml)

5-10

87,000

11-25

21,400

26-50

1,510

51-100

225

101 and greater

21

  1. If contamination level does not meet levels defined in Table 1, do the steps that follow:

    1. Replace the hydraulic pump.

    2. Repeat steps 1 through 13.

Requirements after job completion

Required Conditions

Action/ConditionProcedure/Data

Check fluid level of hydraulic system