Flushing the hydraulic system
Last updated
Last updated
Extraction syringe
Commercial
1
Syringe 7075 from CTA Manufacturing Corp or equivalent.
Container
Commercial
1
.
Set hydraulic pressure on cart to 400 psi and flow rate at 2.0 GPM +/- 0.5 GPM and cycle the actuators to full stroke for 5 minutes.
.
Repeat step 3.
Disconnect the pressure line (to HRFM) at the hydraulic pump, pressure filter assembly, and check valve and allow draining.
.
.
Reconnect the suction (M206-20H102-041) and pressure lines (M206-20H101-041) to the pump.
.
Turn the rotor by hand to remove air.
.
Do a 15-minute ground run of the helicopter.
Take fluid samples from the HRFM reservoir and analyze for particle contamination. Contamination level shall be less than the levels defined in .
5-10
87,000
11-25
21,400
26-50
1,510
51-100
225
101 and greater
21
Replace the hydraulic pump.
Repeat steps 1 through 13.
Check fluid level of hydraulic system
If contamination level does not meet levels defined in , do the steps that follow: