Flushing the hydraulic system
Preliminary requirements
Support equipment
Extraction syringe
Commercial
1
Syringe 7075 from CTA Manufacturing Corp or equivalent.
Container
Commercial
1
Spares
Procedure
It is normal for the reservoir to fill and overflow at the inlet when using the HPU. The time to fill is dependent on the length
Set hydraulic pressure on cart to 400 psi and flow rate at 2.0 GPM +/- 0.5 GPM and cycle the actuators to full stroke for 5 minutes.
Repeat step 3.
Disconnect the pressure line (to HRFM) at the hydraulic pump, pressure filter assembly, and check valve and allow draining.
Reconnect the suction (M206-20H102-041) and pressure lines (M206-20H101-041) to the pump.
Turn the rotor by hand to remove air.
Do a 15-minute ground run of the helicopter.
Take fluid samples from the HRFM reservoir and analyze for particle contamination. Contamination level shall be less than the levels defined in Table 1.
Table 1. Cleanliness Requirements for Synthetic Hydrocarbon Based Hydraulic Fluid Systems
5-10
87,000
11-25
21,400
26-50
1,510
51-100
225
101 and greater
21
If contamination level does not meet levels defined in Table 1, do the steps that follow:
Replace the hydraulic pump.
Repeat steps 1 through 13.
Requirements after job completion
Required Conditions
Check fluid level of hydraulic system